OUTPUT
 
AC Power: 
0 to 280V AC
30A peak
DC Power: 
0 to 280V DC
30A peak
Ripple: 
 < 2%


MEASUREMENT 
Readout:
3 digit backlight LCD display
Resolution:
1V steps
Displayed Values:
AC Voltage
AC Current
DC Voltage
DC Current
Accuracy:

+/- 1% of displayed value


 

PS - 100 Speciafication

 

 

OPERATING VOLTAGES 
Fixed Prime Power:220 to 240V 50/60Hz
or
110 to 120V 50/60Hz
Auto-sensing

ENVIRONMENTAL
 
Operating
Temperature:
-20ºC to +70ºC (-4ºF to +158ºF)
Humidity:0 to 97% RH non-condensing
Isolation:2kV rms for 1 minute
Surge Withstand
Transient:
To IEC 801-5.  1.2/50mS
Common Mode:  Severity level class 4.  Series Mode:  Severity level class 3
Fast Transient Burst: To IEC 801-4 level 3
RFI Immunity: To IEC801-3 level 3.  10V/m 26-1000MHz
Emissions:To EN50081-1: 1992


MECHANICAL DETAILS
 
 Weight:  < 20Kg
 Carry Case: Reinforced aluminium, 340mm x 240mm x 150mm

PS 100 Alu Case

 

DUE TO CONTINUING DEVELOPMENT AND IMPROVEMENTS WEIS RESERVES THE RIGHT TO CHANGE THIS SPECIFICATION WITHOUT NOTICE